Rev Acta Médica 2021; 22 (2)

Effectiveness of The Holladay II Formula in Calculating Diopter Power of The Intraocular Lens

Ballate NEM, Ventura FCA, Pérez GD, Tamargo BTO, de la Torre LN, Sosa GI, Novoa SE
Full text How to cite this article

Language: Spanish
References: 15
Page:
PDF size: 179.32 Kb.


Key words:

Holladay I, Holladay II, SRK-T, Hoffer Q, Residual spherical defect intraocular lens, Diopter Power of The Intraocular Lens (LIO).

ABSTRACT

Introduction: The calculation of the dioptric power of the intraocular lens is the determining factor of the postoperative refractive condition in patients, and the selection of the appropriate formula is crucial.
Objective: To evaluate the effectiveness of Holladay II formula in calculating the dioptric power of the intraocular lens.
Methods: A longitudinal comparative descriptive study was carried out, 40 eyes distributed in three groups according to the axial length were evaluated, which underwent the extraction of the lens and the implantation of the intraocular lens. These lenses were calculated with a formula chosen at random to determine the effectiveness. The residual spherical defect, the estimated spherical defect and the optimal spherical difference were evaluated three months after surgery.
Results: The Holladay II formula was effective in all axial lengths for the residual spherical defect, the Hoffer Q in the low and normal axial lengths, and the SRK-T was effective in the normal and high axial length. The Holladay II was effective at the low axial length for optimal spherical difference, less effective than the Hoffer Q at the normal axial length, and effective at the high axial length.
Conclusions: The Holladay II formula was effective in all axial lengths with a refractive defect considered Emmetropic.


REFERENCES

  1. Jeong J, Song H, Lee JK, Chuck RS, Kwon JW. The effect of ocular biometricfactors on the accuracy of various IOL power calculation formulas. BMCophthalmology. 2017[acceso:22/06/2021];7(1):62. Disponible en:https://bmcophthalmol.biomedcentral.com/track/pdf/10.1186/s12886-017-0454-y.pdf

  2. Ballate NEM, Jiménez PR, Sosa GI, Borges PS, Márquez FM, Díaz RA. Defectosesféricos residuales: diferencias entre el valor dióptrico del lente antes ydespués de la operación de catarata. Revista Acta Médica.2017[acceso:22/06/2021];8(1):13-19. Disponible en:https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=.+Revista+Acta+M%C3%A9dica.+2017%3B8%281%29%3A13-19.&btnG

  3. Mueller A, Thomas BC, Auffarth GU, Holzer MP. Comparison of a new imageguidedsystem versus partial coherence interferometry, Scheimpflug imaging, andoptical low-coherence reflectometry devices: keratometry and repeatability.Journal of Cataract & Refractive Surgery. 2016[acceso:22/06/2021];42(5):672-8.Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Journal+of+Cataract+%26+Refractive+Surgery.+2016%3B42%285%29%3A672-8.&btnG

  4. Ronald B. Melles, Jack T Holladay, William J. Chang. Accurancy of IntraocularLens Calculation Formulas. American Academy of Ophthalmology. 2017;8:27.DOI: http://dx.doi.org/10.1016/j.ophtha.2017

  5. Abulafia A, Barrett GD, Koch DD, Wang L, Assia EI. Protocols for Studies ofIntraocular Lens Formula Accuracy. American journal of ophthalmology.2016[acceso:22/06/2021];164:149-50. Disponible en:https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=50.Journal+of+Cataract+%26+Refractive+Surgery.+2016%3B42%285%29%3A672-8.&btnG

  6. Olsen T. Calculation of intraocular lens power: a review Acta OphthalmolScand. 2007[acceso:22/06/2021];85(5):472-85. Disponible en:https://scholar.google.es/scholar?protocols+for+Studies+of+Intraocular+Lens+Formula+Accuracy.+American+journal+of+ophthalmology.+2016%3B164%3A149-

  7. Melles RB, Holladay JT, Chang WJ. Accuracy of Intraocular Lens CalculationFormulas. Ophthalmology. 2018[acceso:22/06/2021];125:169-78. Disponible enhttps://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=.+Accuracy+of+Intraocular+Lens+Calculation+Formulas.+Ophthalmology.+2018%3B125%3A169-78

  8. Cordelette C, Arndt C, Vidal J, Afriat M, Durbant E, et al. Is Holladay 2formula acurate enough for calculating intraocular lens power in non-standardeyes. Journal Français d’Ophtalmologie. 2018[acceso:22/06/2021];41(4):308-14.Disponible en:https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=.+Accuracy+of+Intraocular+Lens+Calculation+Formulas.+Ophthalmology.+2018%3B125%3A169-

  9. Hoffer KJ, Savini G. IOL Power Calculation in Short and Long Eyes. Asia Pac JOphthalmol (Phila). 2017[acceso:22/06/2021];6(4):330-1. Disponible en:https://scholar.google.es/scholar?review+Acta+Ophthalmol+Scand.+2007%3B85%285%29%3A472-

  10. Aramberri J. Bases ópticas para comprender el cálculo de la lenteintraocular. En: Ruiz Mesa R, Taña Rivero Pedro. Óptica para el cirujanofacorrefractivo. España, Barcelona: Elsevier; 2015[acceso:22/06/2021]. pp. 391-3. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q

  11. Cooke DL. Unexpectedly low power formula lens constants. Journal ofCataract & Refractive Surgery. 2017[acceso:22/06/2021];43(3):433. Disponibleen:https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Unexpectedly+low+power+formula+lens+constants.+Journal+of+Cataract+%26+Refractive+Surgery.+2017%3B43(3)%3A433&btnG

  12. Jack Kane, Anton Van Heerden, Alp Atik. Intraocular lens power formulaaccuracy: comparison of 7 formulas Constantinos Petsoglou. Journal of Cataractand Refractive Surgery. 2016[acceso: 22/06/2021];42(10):1490-1500. Disponibleen:https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Intraocular+lens+power+formula+accuracy%3A+comparison+of+7+formulas+Constantinos+Petsoglou.+Journal+of+Cataract+and+Refractive+Surgery.+2016%3B42%2810%29%3A1490-

  13. Evdoxia Terzi, Li Wang, Thomas Kohnen. Accuracy of modern intraocular lenspower calculation formulas in refractive lens exchange for high myopia and highhyperopia. Journal of cataract and Refractive Surgery.2009[acceso:22/06/2021];35(7):1181-9. Disponible en:https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Accuracy+of+modern+intraocular+lens+power+calculation+formulas+in+refractive+lens+exchange+for+high+myopia+and+high+hyperopia.+Journal+of+cataract+and+Refractive+Surgery.+2009%3B35%287%29%3A1181-

  14. Cooke DL, Cooke TL. Comparison of 9 intraocular lens power calculationformulas. Journal of Cataract & Refractive Surgery.2016[acceso:22/06/2021];42(8):1157-64. Disponible en:https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=Comparison+of+9+intraocular+lens+power+calculation+formulas.+Journal+of+Cataract+%26+Refractive+Surgery.+2016%3B42%288%29%3A1157-64.&btnG

  15. Hill Garg. IOL calculations: U.S. and international surgeons differ on formulapreference EyeWorld news magazine 2015[Acceso: 22/06/2021]. Disponible en:https://www.eyeworld.org/article-iol-calculations--u-s--and-internationalsurgeons-differ-on-formula-preference




2020     |     www.medigraphic.com

Mi perfil

CÓMO CITAR (Vancouver)

Rev Acta Médica. 2021;22