medigraphic.com
SPANISH

Revista Cubana de Estomatología

ISSN 1561-297X (Print)
  • Contents
  • View Archive
  • Information
    • General Information        
    • Directory
  • Publish
    • Instructions for authors        
  • medigraphic.com
    • Home
    • Journals index            
    • Register / Login
  • Mi perfil

2021, Number 2

<< Back Next >>

Rev Cubana Estomatol 2021; 58 (2)

Survival rate of feldspathic and reinforced feldspathic ceramic single-unit fixed prostheses

Libedinsky J, Schlesinger N, Chaple GAM, Fernández E, Jorquera G
Full text How to cite this article

Language: Spanish
References: 31
Page:
PDF size: 769.18 Kb.


Key words:

computer-aided design, ceramic, fixed partial denture, prosthesis precision adjustment, prostheses and implants, prosthesis design, prosthesis failure, dental prosthesis retention, dental prosthesis design.

ABSTRACT

Introduction: Thanks to its efficiency and the exclusive use of metal-free ceramics, in oral rehabilitation it has been possible to achieve aesthetic and mechanical standards, maintaining or even exceeding the quality of the treatments compared to traditional metal-ceramic restorations. Currently, free ceramic manufacturing mechanisms are increasingly evolving towards CAD-CAM machined technologies and decreasing their conventional production through the PRESS Injection technique.
Objective: Compare the survival rate of single-unit fixed prostheses made with conventional feldspathic ceramics and reinforced with lithium disilicate by the CEREC® CAD/CAM chairside system, with the conventional PRESS laboratory injection method.
Methods: A systematic review was conducted of scientific evidence included in papers published until the year 2019 in PubMed, PubMed Clinical Queries, Epistemonikos, Tripdatabase, Cochrane Library, electronic resources of Los Andes Peruvian University, and retrograde bibliography. The papers selected dealt with conventional and lithium-disilicate reinforced feldspathic ceramic single-unit prostheses made by CAD/CAM and/or the conventional method.
Results: A total 28 papers met the inclusion criteria. Of these, 21 were observational cohort studies, four were randomized clinical assays and three were non-randomized assays. Short- and mid-term, CEREC® CAD/CAM achieved survival rates of 98% and 91.9%, respectively. The conventional system achieved survival rates of 97.5% short-term and 93% mid-term.
Conclusions: As described in the literature, CEREC® CAD/CAM had a slightly higher survival rate than the conventional system in the short term. In the medium term, however, CEREC® CAD/CAM displayed a slight reduction in comparison with the conventional system. No studies are available to determine the clinical survival of the treatments in the long term.


REFERENCES

  1. Silva LHD, Lima E, Miranda RBP, Favero SS, Lohbauer U, Cesar PF. Dental ceramics: a review of new materials and processing methods. Braz Oral Res. 2017;31(suppl 1):e58. PMID: 28902238

  2. Fasbinder DJ. Clinical performance of chairside CAD/CAM restorations. J Am Dent Assoc. 2006;137 Suppl:22s-31s. PMID: 20516109

  3. Rauch A, Reich S, Schierz O. Chair-side generated posterior monolithic lithium disilicate crowns: clinical survival after 6 years. Clin Oral Investig. 2017;21(6):2083-9. PMID: 27891569

  4. Rauch A, Reich S, Dalchau L, Schierz O. Clinical survival of chair-side generated monolithic lithium disilicate crowns:10-year results. Clin Oral Investig . 2018;22(4):1763-9. PMID: 29103104

  5. Reich S, Schierz O. Chair-side generated posterior lithium disilicate crowns after 4 years. Clin Oral Investig . 2013;17(7):1765-72. PMID: 23135425

  6. Seydler B, Schmitter M. Clinical performance of two different CAD/CAM-fabricated ceramic crowns: 2-Year results. J Prosthet Dent. 2015;114(2):212-6. PMID: 25935085

  7. Fasbinder DJ, Dennison JB, Heys D, Neiva G. A clinical evaluation of chairside lithium disilicate CAD/CAM crowns: a two-year report. J Am Dent Assoc . 2010;141(Suppl 2):10s-4s. PMID: 20516109

  8. Aziz A, El-Mowafy O, Tenenbaum HC, Lawrence HP, Shokati B. Clinical performance of chairside monolithic lithium disilicate glass-ceramic CAD-CAM crowns. J Esthet Restor Dent. 2019;31(6):613-9. PMID: 31565848

  9. Bindl A, Richter B, Mormann WH. Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry. Int J Prosthodont. 2005;18(3):219-24. PMID: 15945309

  10. Fages M, Raynal J, Tramini P, Cuisinier FJ, Durand JC. Chairside Computer-Aided Design/Computer-Aided Manufacture All-Ceramic Crown and Endocrown Restorations: A 7-Year Survival Rate Study. Int J Prosthodont . 2017;30(6):556-60. PMID: 29084297

  11. Otto T, Mormann WH. Clinical performance of chairside CAD/CAM feldspathic ceramic posterior shoulder crowns and endocrowns up to 12 years. Int J Comput Dent. 2015;18(2):147-61. PMID: 26110927

  12. Otto T. Computer-aided direct all-ceramic crowns: preliminary 1-year results of a prospective clinical study. Int J Periodontics Restorative Dent. 2004;24(5):446-55. PMID: 15506025

  13. Bindl A, Mormann WH. Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years. Eur J Oral Sci. 2004;112(2):197-204. PMID: 15056119

  14. Valenti M, Valenti A. Retrospective survival analysis of 261 lithium disilicate crowns in a private general practice. Quintessence Int. 2009;40(7):573-9. PMID: 19626232

  15. Marquardt P, Strub JR. Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study. Quintessence Int. 2006;37(4):253-9. PMID: 16594356

  16. Toksavul S, Toman M. A short-term clinical evaluation of IPS Empress 2 crowns. Int J Prosthodont . 2007;20(2):168-72. PMID: 17455438

  17. Toman M, Toksavul S. Clinical evaluation of 121 lithium disilicate all-ceramic crowns up to 9 years. Quintessence Int. 2015;46(3):189-97. PMID: 25529004

  18. Teichmann M, Gockler F, Weber V, Yildirim M, Wolfart S, Edelhoff D. Ten-year survival and complication rates of lithium-disilicate (Empress 2) tooth-supported crowns, implant-supported crowns, and fixed dental prostheses. J Dent. 2017;56:65-77. PMID: 27984088

  19. Mansour YF, Al-Omiri MK, Khader YS, Al-Wahadni A. Clinical performance of IPS-Empress 2 ceramic crowns inserted by general dental practitioners. J Contemp Dent Pract. 2008;9(4):9-16. PMID: 18473022

  20. Gehrt M, Wolfart S, Rafai N, Reich S, Edelhoff D. Clinical results of lithium-disilicate crowns after up to 9 years of service. Clin Oral Investig . 2013;17(1):275-84. PMID: 22392163

  21. Taskonak B, Sertgoz A. Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures. Dent Mater. 2006;22(11):1008-13. PMID: 16375961

  22. Yang Y, Yu J, Gao J, Guo J, Li L, Zhao Y, et al. Clinical outcomes of different types of tooth-supported bilayer lithium disilicate all-ceramic restorations after functioning up to 5 years: A retrospective study. J Dent . 2016;51:56-61. PMID: 27263032

  23. Saleh Samer M, Ali TT, Abdullah H. Clinical Outcomes of Lithium Disilicate Single Crowns after a Mean Duration of 3 Years - A Retrospective Study. Oral Health Prev Dent. 2018;16(3):249-57. PMID: 30027164

  24. Huettig F, Gehrke UP. Early complications and performance of 327 heat-pressed lithium disilicate crowns up to five years. J Adv Prosthodont. 2016;8(3):194-200. PMID: 27350853

  25. Schmitz JH, Beani M. Effect of different cement types on monolithic lithium disilicate complete crowns with feather-edge preparation design in the posterior region. J Prosthet Dent . 2016;115(6):678-83. PMID: 26724849

  26. Schmitz JH, Cortellini D, Granata S, Valenti M. Monolithic lithium disilicate complete single crowns with feather-edge preparation design in the posterior region: A multicentric retrospective study up to 12 years. Quintessence Int. 2017:601-8. PMID: 28740971

  27. Etman MK, Woolford MJ. Three-year clinical evaluation of two ceramic crown systems: a preliminary study. J Prosthet Dent . 2010;103(2):80-90. PMID: 20141812

  28. Simeone P, Gracis S. Eleven-Year Retrospective Survival Study of 275 Veneered Lithium Disilicate Single Crowns. Int J Periodontics Restorative Dent . 2015;35(5):685-94. PMID: 26357698

  29. Valenti M, Valenti A. Retrospective survival analysis of 110 lithium disilicate crowns with feather-edge marginal preparation. Int J Esthet Dent. 2015;10(2):246-57. PMID: 25874272

  30. Rodrigues SB, Franken P, Celeste RK, Leitune VCB, Collares FM. CAD/CAM or conventional ceramic materials restorations longevity: a systematic review and meta-analysis. J Prosthodont Res. 2019;63(4):389-95. PMID: 31303569

  31. Akin A, Toksavul S, Toman M. Clinical Marginal and Internal Adaptation of Maxillary Anterior Single All-Ceramic Crowns and 2-year Randomized Controlled Clinical Trial. J Prosthodont. 2015;24(5):345-50. PMID: 25220298




2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

Rev Cubana Estomatol. 2021;58