Non-infectious dermatological complications of orthopedic implants: a literatura review
Ramírez-Macía A, Quiroz-Fino Nerly-Janeth
Language: Spanish
References: 39
Page: 503-508
PDF size: 639.90 Kb.
ABSTRACT
Introduction: the overall prevalence of hypersensitivity to metal components has been estimated at approximately 10 to 15%.
Objective: the objective of this review is to describe the hypersensitivity reactions that occur secondary to the implantation of orthopedic prosthetic devices in arthroplasty surgery.
Materials and methods: an open search was performed in the databases EBSCO, PubMed-Medline, Google academic, SciELO, Embase biomedical and Cochrane Library with the terms Arthroplastym, hy-persensitivity, prostheses and implants, in the English and Spanish languages, without limiting the level of evidence.
Results: thirty nine articles were found with important information for the current review.
Conclusions: skin hypersensitivity reactions to metal are infrequent, so more common inflammatory causes such as infection, instability, loosening or malrotation of the implant, among others, should be excluded before con-sidering such a pathology. Currently there is no gold standard regarding the diagnosis, treatment or prevention of hypersensitivity.
REFERENCES
Mulhall K, Ghomrawi H, Scully S, Callaghan JJ, Saleh KJ. Current etiologies and modes of failure in total knee arthroplasty revision. Clin Orthop Relat Res. 2006; 446(446):45–50. DOI: 10.1097/01.blo.0000214421.21712.62
Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KJ. Patient satisfaction after total knee arthroplasty: Who is satisfied and who is not? Clin Orthop Relat Res. 2010; 468(1):57–63. DOI:10.1007/s11999-009-1119-9
Haidukewych GJ, Jacofsky DJ, Pagnano MW, Trousdale RT. Functional results after revision of well-fixed components for stiffness after pri-mary total knee arthroplasty. J Arthroplasty. 2005; 20(2):133–138. DOI: 10.1016/j.arth.2004.09.057
Merritt K, Rodrigo JJ. Immune response to synthe-tic materials: Sensitization of patients receiving orthopaedic implants. Clin Orthop Relat Res. 1996; 326:71–79.
Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am. 2001; 83(3):428–436. DOI: 10.2106/00004623-200103000-00017
Granchi D, Cenni E, Tigani D, Trisolino G, Baldini N, Giunti A. Sensitivity to implant materials in patients with total knee arthroplasties. Biomate-rials. 2008; 29(10):1494–1500. DOI: 10.1016/j.biomaterials.2007.11.038
Niki Y, Matsumoto H, Otani T, Yatabe T, Kondo M, Yoshimine F, et al. Screening for symptomatic metal sensitivity: A prospective study of 92 patients undergoing total knee arthroplasty.Biomaterials. 2005; 26(9):1019–1026. DOI: 10.1016/j.biomaterials.2004.03.038
Verma SB, Mody B, Gawkrodger DJ. Dermatitis on the knee following knee replacement: A minori-ty of cases show contact allergy to chromate, cobalt or nickel but a causal association is un-proven.Contact Dermatitis. 2006; 54(4):228–22
DOI: 10.1111/j.0105-1873.2006.0775o.x9. Handa S, Dogra S, Prasad R. Metal sensitivity in a patient with a total knee replacement.Contact Dermatitis. 2003; 49(5):259–260. https://doi.org/10.1111/j.0105-1873.2003.0225b.x
Beecker J, Gordon J, Pratt M. An interesting case of joint prosthesis allergy. Dermatitis. 2009; 20(2):E4–E9.
Gao X, He R, Yan S, Wu L. Dermatitis associated with chromium following total knee arthroplasty. J Arthroplasty. 2011; 26(4):665e13-665e16. DOI: 10.1016/j.arth.2010.06.002
Anand A, McGlynn F, Jiranek W. Metal hypersen-sitivity: Can it mimic infection?. J Arthroplas-ty. 2009; 24(5):826e25-826.e28. DOI: 10.1016/j.arth.2008.05.002
Morwood MP, Garrigues GE. Shoulder arthroplas-ty in the patient with metal hypersensitivity.J Shoulder Elbow Surg. 2015; 24(7):1156–1164. DOI: 10.1016/j.jse.2015.01.015
Disegi JA, Eschbach L. Stainless steel in bone surgery. Injury. 2000; 31(Suppl.4):2–6. DOI: 10.1016/S0020-1383(00)80015-7
Teo WZ, Schalock PC. Metal Hypersensitivity Reactions to Orthopedic Implants. Dermatol Ther (Heidelb). 2017; 7(1):53-64. DOI: 10.1007/s13555-016-0162-1
Lachiewicz PF, Watters TS, Jacobs JJ. Metal Hy-persensitivity and Total Knee Arthroplasty. J Am Acad Orthop Surg. 2016; 24(2):106-112. DOI: 10.5435/JAAOS-D-14-00290
Mahendra G, Pandit H, Kliskey K, Murray D, Gill HS, Athanasou N. Necrotic and inflammatory changes in metal-on-metal resurfacing hip ar-throplasties. Acta Orthop. 2009; 80(6):653–659. DOI: 10.3109/17453670903473016
Fang CS, Harvie P, Gibbons CL, Whitwell D, Atha-nasou NA, Ostlere S. The imaging spectrum of peri-articular inflammatory masses following metal-on-metal hip resurfacing. Skeletal Radiol. 2008; 37(8):715–722. DOI: 10.1007/s00256-008-0492-x
Willert HG, Buchhorn GH, Fayyazi A, Flury R, Win-dler M, Koster G, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005; 87(1):28–36. DOI: 10.2106/JBJS.A.02039pp
Mikhael MM, Hanssen AD, Sierra RJ. Failure of metal-on-metal total hip arthroplasty mimicking hip infection. A report of two cases.J Bone Joint Surg Am. 2009; 91(2):443–446. DOI: 10.2106/JBJS.H.00603
Campbell P, Shimmin A, Walter L, Solomon M. Metal sensitivity as a cause of groin pain in metal-on-metal hip resurfacing. J Arthroplasty. 2008; 23(7):1080–1085. DOI: 10.1016/j.arth.2007.09.024
Jensen P, Thyssen JP, Retpen JB, Menne T. Cobalt allergy and suspected aseptic lymphocyte-dominated vascular-associated lesion following total hip arthroplasty.Contact Dermatitis. 2009; 61(4):238–239. DOI: 10.1111/j.1600-0536.2009.01599.x
Counsell A, Heasley R, Arumilli B, Paul A. A groin mass caused by metal particle debris after hip re-surfacing. Acta Orthop Belg. 2008; 74(6):870–874.
Rostoker G, Robin J, Binet O, Blamoutier J, Paupe J, Lessana-Leibowitch M, et al. Dermatitis due to orthopaedic implants: a review of literature and report of three cases. J Bone Joint Surg. 1987; 69(9):1408–1412.
Merle C, Vigan M, Devred D, Girardin P, Adessi B, Laurent R. et al. Generalized eczema from Vitallium osteosynthesis material. Contact Der-matitis. 1992; 27(4):257–258. DOI: 10.1111/j.1600-0536.1992.tb03259.x
Ridley CM. How relevant is cobalt sensitivity in a patient with unsatisfactory total knee replace-ment?. Clin Exp Dermatol. 1977; 2(4):401-404. DOI: 10.1111/j.1365-2230.1977.tb01582.x
Symeonides PP, Paschaloglu C, Papageorgiou S. An allergic reaction after fixation of a fracture using a Vitallium plate.J Allergy Clin Immunol. 1973; 51(4):251–252. DOI: 10.1016/0091-6749(73)90145-0
Munro-Ashman D, Miller AJ. Rejection of metal to metal prosthesis and skin sensitivity to co-balt. Contact Dermatitis. 1976; 2(2):65–67. DOI: 10.1111/j.1600-0536.1976.tb02986.x
Bergschmidt P, Bader R, Mittelmeier W. Metal hy-persensitivity in total knee arthroplasty: Revision surgery using a ceramic femoral component. The Knee. 2012; 19(2):144–147. DOI: 10.1016/j.knee.2011.01.001
McMaster WC, Patel J. Adverse local tissue res-ponse lesion of the knee associated with Morse taper corrosion. J Arthroplasty. 2013; 28(2):375.e5-375.e8. DOI: 10.1016/j.arth.2012.04.005
Thakur R, Ast M, McGraw M, Bostrom M, Rodriguez J, Parks M. Severe persistent synovitis after cobalt-chromium total knee arthroplasty requi-ring revision. Orthopedics. 2013; 36(4):520–524. DOI: 10.3928/01477447-20130327-34
Thomsen M, Rozak M, Thomas P. Pain in a chromium-allergic patient with total knee ar-throplasty: Disappearance of symptoms after revision with a special surface-coated TKA. A case report.Acta Orthop. 2011; 82(3):386–388. DOI: 10.3109/17453674.2011.579521
Thyssen JP, Jakobsen SS, Engkilde K, Johansen JD, Soballe K, Menne T. The association bet-ween metal allergy, total hip arthroplasty, and revision. Acta Orthop. 2009; 80(6):646–652. DOI: 10.3109/17453670903487008
Park Y, Moon Y, Lim S, Yang J, Ahn G, Choi Y. Early osteolysis following second-generation metal-on-metal hip replacement.J Bone Joint Surg Am. 2005; 87(7):1515–1521. DOI: 10.2106/JBJS.D.02641
Antony FC, Holden CA. Metal allergy resurfaces in failed hip endoprostheses. Contact Dermati-tis. 2003; 48(1):49–50. DOI: 10.1034/j.1600-0536.2003.480108_4.x
Milavec-Puretic V, Orlic D, Marusic A. Sensitivity to metals in 40 patients with failed hip endo-prosthesis. Arch Orthop Trauma Surg. 1998; 117(6-7):383–386. DOI: 10.1007/s004020050272
Phedy P, Djaja YP, Boedijono DR, Wahyudi M, Sili-tonga J, Solichin I. Hypersensitivity to orthopaedic implant manifested as erythroderma: Timing of implant removal. Int J Surg Case Rep. 2018; 49:110-114. DOI: 10.1016/j.ijscr.2018.06.011
Basko-Plluska JL, Thyssen JP, Schalock PC. Cuta-neous and systemic hypersensitivity reactions to metallic implants. Dermatitis. 2011; 22(2):65–79. DOI: 10.2310/6620.2011.10055
Nakamura S, Yasunaga Y, Ikuta Y, Shimogaki K, Hamada N, Takata N. Autoantibodies to red cells associated with metallosis—a case report.Acta Orthop Scand. 1997; 68(5):495–496 DOI: 10.3109/17453679708996269