2007, Number 2
<< Back Next >>
Rev Mex Pediatr 2007; 74 (2)
Haemoglobin and body temperature on the determination of blood gases in neonates
Caballero-Noguéz B, Flores CI
Language: Spanish
References: 19
Page: 66-69
PDF size: 54.00 Kb.
ABSTRACT
Objective. To evaluate the utility of processing the blood samples for determination pH, arterial oxygen pressure (PaO
2) and arterial carbon dioxide (PaCO
2) with the real values of hemoglobin and temperature.
Material and methods. 90 newborns, in the first week of life, with mechanical ventilation. They were formed three constituted homogeneous groups in the following way: group I patient’s hemoglobin and temperature; group II with constant hemoglobin and the patient’s temperature; group III patient’s hemoglobin and constant temperature. They were measured the value of the pH, PaO
2 and PaCO
2.
Results. The group I and the group III showed a significant p ‹ 0.01 and p ‹ 0.05, respectively, with regard to the group II. The groups I and III didn’t show significant differences during the study.
Conclusions. The adjustment in the hemoglobin showed to be the factor that contributes to modify the results in the values of the pH, PaO
2 and PaCO
2. Attributable secondary complications were not existed to the extraction of the blood samples.
REFERENCES
James LS, Weisbort IM, Prince CE. The acid-base status of human infants in relation to birth asphysia and the onset of respiration. J Pediatr 1958; 52: 379-82.
Bowe ET, Beard RW, Finster M. Reability of fetal blood samples. Am J Obstet Gynecol 1970; 107: 297-301.
Stamm O, Latscha V, Janace KP. Development of a special electrode for continuous subcutaneous pH measurement in the infant scalp. Am J Obstet Gynecol 1976; 124: 193-195.
Siggard-Anderson O. Blood acid-base alignment nomogram. Scales for pH, PCO2, bases excess of whole blood of different hemoglobin concentrations, plasma bicarbonate and plasma total CO2. Scand J Clin Lab Invest 1963; 15: 211-16.
Giar MH, Pernn F, Maraval G. An anatomic control system of O2 and CO2 concentration of artificially ventilated patients. Intens Care Med 1980; 6: 81-5.
Clarck LC. Monitor and control of blood and tissue oxygen tensions. Trans Am Soc Artif Intern Organs 1956; 2: 41-5.
Sanz MC. Ultramicro methods and standardization of equipment. Clin Chem 1957; 22: 5758.
Severinghaus JW. Blood gas calculator. J Appl Physiol 1966; 21: 1108-10.
Severinghaus JW. Simple accurate equations for human blood O2 dissociation computations. J Appl Physiol 1979; 46: 599-602.
Leland LF, Dellinger KT, Mills AL. Potential errors in neonatal blood gas measurements. J Pediatr 1980; 97: 650-2.
Hansen JE, Simmons DH. A systematic error in the determination of blood PCO2. Am Rev Respir Dis 1977; 115: 1061-4.
Dennis RC, Ng R, Veston NS. Effect of sample dilutions on arterial blood gas determinations. Crit Care Med 1985; 13: 1067-71.
Neff GW, Radke WA, Sambucetti CJ. A computer assisted electrode system for measuring blood pH, PO2, PCO2, sodium and potassium. Clin Chem 1970; 16: 566-71.
Shapiro AB, Harrison AR, Walton RJ. Manejo clínico de los gases sanguíneos. 3a ed. México: Editorial Panamericana, 1984: 157.
Fletcher G, Barber JL. Effect sampling technique on the determination of PO2 during oxygen brathing. J Appl Physiol 1966; 21: 463-7.
Douglas IHS. Monitoreo de la ventilación. En: Shoemaker WC, Thomson WL, Holbrook PR, eds. Tratado de medicina crítica y terapia intensiva. Buenos Aires: Panamericana, 1989; 19: 177-94.
Ronco JJ, Fenwick JC, Tweeddale MG, Wiggs BR, Phang PT, Cooper DJ, Cunningham KF, Russell JA, Walley KR. Identification of the critical oxygen delivery for anaerobic metabolism in critically ill septic and nonseptic humans. JAMA 1993; 270; 1724-30.
Marik PE, Sibbald WJ. Effect of store-blood transfusion on oxygen delivery in patients with sepsis. JAMA 1993; 269: 3024-29.
Hayes MA, Timmins AC, Yau EHS, Palazzo M, Hinds CJ, Watson D. Elevation of systemic oxygen delivery in the treatment of critically ill patients. N Engl J Med 1994; 330: 1717-22.