2022, Number 4
Characterization of pleural and ascites effusions using concentration of their proteins and their comparison with current criteria
Language: Spanish
References: 18
Page:
PDF size: 241.51 Kb.
ABSTRACT
Introduction: Serous fluids are classified as exudates/ transudates based on protein concentration and other criteria that have a large margin of error. Subsequently, criteria were tested separately for pleural fluids in 1972 by Light et al and for ascitic fluids in 1992 the Runyon criteria with respective sensitivities of 98 % for the first and 97 % for the second. Currently, the primary criterion continues to be applied with an error of up to 40 %.Objective: To identify the margin of error in the classification of pleural and ascitic fluids when using the classical criteria (Starling) with respect to the current criteria of Light and Runyon using nationally produced reagents.
Methods: 185 fluid samples were studied - 121 pleural and 64 ascitic - in the period 2017/2022 at the Miguel Enriquez Clinical Surgical Teaching Hospital in Havana.
Results: Discordances were found in the classification of exudates / transudates of liquids using the different differentiation methods, important in the clinical diagnosis, concluding that using the classic criterion of Starling proteins, 9,1 % and 17,2 % of the pleural and ascitic effusions had errors in their classification as exudate and/or transudate.
Conclusion: The margin of error in the classification of pleural and ascitic fluids ranged from 9-17% when the classical criteria of proteins (Starling) is used with respect to the current criteria of Light and Runyon.
REFERENCES
Douhal Y, Villar Fernández A, Gaspar Blázquez MJ, Granados Carreño R, Pascual Tomas TJ. Importancia de la citología en los líquidos biológicos. Estudio de adenocarcinoma en liquido pericárdico. Rev Bioanálisis. 2022 [acceso 29/07/2022];25. Disponible en: http://www.revistabioanalisis.com/images/Rev%20125n/nota%204.pdf6.
Runyon BA, Montano AA, Akriviadis EA, Antillon MR, Irving MA, Mc Hutchinson JG. The serum-ascitis albumin gradient is superior to the exudate-transudate concept in the differential diagnosis of ascitis. Ann Intern Med. 1992 [acceso 08/07/2022];117(3):215-20. Disponible en: https://www.ncbi.nlm.nih.gov/pubmed/16162159.
Rodríguez Vargas BO, Monge Salgado E, Montes Teves P, Salazar Ventura S, Guzmán Calderón E. Eficacia de la gradiente de albúmina sangre-ascitis y los análisis de proteínas en líquido ascítico en el diagnóstico de ascitis hipertensiva portal. Rev Gastroenterol Peru. 2014 [acceso 08/07/2022];34(1):23-8. Disponible en http://www.scielo.org.pe/scielo.php?script=sci_arttext&pid=S1022-5129201400010000310.
Ruiz García R, Márquez de Prado Urquía MM, Borque de Larrea L. Separación de trasudados y exudados pleurales mediante la cuantificación de parámetros bioquímicos. Rev Clin Esp. 2004 [acceso 22/07/2022];204(10). Disponible en: http://www.elsevier.es/index.php?p=revista&pRevista=pdf-simple&pii=13066174&r=32113.
De Sousa Amorím E. Evolución de la función peritoneal a largo plazo de los pacientes tratados con diálisis peritoneal. Desarrollo de nuevas estrategias para mejorar la viabilidad de la membrana y minimizar las consecuencias relacionadas con la técnica [tesis]. Madrid: Universidad Autónoma de Madrid; 2013 [acceso 22/07/2022]. Disponible en: https://scholar.google.es/scholar?hl=es&as_sdt=0%2C5&q=poro+membrana+peritoneal++medida+pdf&btnG14.