medigraphic.com
SPANISH

Revista Mexicana de Oftalmología

Anales de la Sociedad Mexicana de Oftalmología y Archivos de la Asociación Para Evitar la Ceguera en México
  • Contents
  • View Archive
  • Information
    • General Information        
    • Directory
  • Publish
    • Instructions for authors        
  • medigraphic.com
    • Home
    • Journals index            
    • Register / Login
  • Mi perfil

2008, Number 3

<< Back Next >>

Rev Mex Oftalmol 2008; 82 (3)

Resultados visuales, refractivos y grado de satisfacción de pacientes sometidos a implante de lente intraocular ReSTOR® (Experiencia 2004-2007)

Vale-Oviedo MA, Martínez-Ramos MC, Claros-Bernal JA, Simón-Campos JA
Full text How to cite this article

Language: Spanish
References: 14
Page: 145-149
PDF size: 72.09 Kb.


Key words:

Facorefractive surgery, multifocal lenses, visual quality.

ABSTRACT

Background: The main goal of the implantation of multifocal lenses is to restore the visual acuity in the presbyopic patient with or without cataract. ReSTOR® lens seems to be one of the most useful to achieve a high satisfaction degree.
Objective: To determine visual quality and satisfaction degree after the implantation of the ReSTOR® lens.
Methodology: Cohort study of patients who underwent ReSTOR® lens implantation. We included patients older than 45 years, who didn’t want to use glasses anymore, with ametropia ≤1diopter and astigmatism ≥1.A complete ophthalmological evaluation was made before and after the surgery. The post operating satisfaction degree was assessed with subjective and objective measurements.
Results: We included 60 patients, mean age (±DE) 57.5 ± 9.6 years. We found a significant improvement after surgery in terms of near vision (0.42 ± 0.16 vs. 0.02 ± 0.06 p‹0.001), distant vision (0.59 ± 0.31 vs. 0.08 ± 0.13 p‹0.001) and refraction (1.4 ± 2.2 vs. 0.31 ± 0.69 p‹0.001). Eighty three percent of patients described a high satisfaction degree and only 4.3% referred disappointment.
Conclusion: Implantation of ReSTOR® lens achieves a high improvement of the visual quality and a high degree of satisfaction in treated patients.


REFERENCES

  1. Montes-Micó R, Alió JL. Distance and near contrast sensitivity function after multifocal intraocular lens implantation. J Cataract Refract Surg 2003; 29:703-711.

  2. Montes-Micó R, España E, Bueno I y cols. Visual performance with multifocal intraocular lenses; mesopic contrast sensitivity under distance and near conditions. Ophthalmology 2004; 111:85-96.

  3. Alfonso JF , Fernández-Vega L , Baamonde MB y cols. Prospective visual evaluation of apodized diffractive intraocular lenses. J Cataract Refract Surg 2007; 33:1235-1243

  4. Alfonso JF , Fernández-Vega L , Baamonde MB y cols. Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens. J Cataract Refract Surg 2007; 33:430-438.

  5. Kohnen T, Allen D, Boureau C y cols. European multicenter study of the Acrysof ReSTOR apodized diffractive intraocular lens. Ophthalmology 2006; 113:578-584.

  6. Javitt JC, Steinert RF. Cataract extraction with multifocal intraocular lens implantation: a multinational clinical trial evaluating clinical, functional and quality-of-life outcomes. Ophthalmology 2000; 107:2040-2048.

  7. Gimbel HV, Sanders DR, Raanan MG. Visual and refractive results of multifocal intraocular lenses. Ophthalmology 1991; 98:881-888.

  8. Davison JA, Simpson MJ . History and development of the apodized diffractive intraocular lens. J Cataract Refract Surg 2006; 32:849-58.

  9. Fernández-Vega L, Alfonso JF, Rodríguez PP y cols. Clear lens extraction with multifocal apodized diffractive intraocular lens implantation. Ophthalmology 2007; 114:1491-1498.

  10. Petermeier K, Szurman P. Subjective and objective outcome following implantation of the apodized diffractive Acrysof ReSTOR. Ophthalmologe 2007; 104:399-404.

  11. Rekas M, Zelichowska B. Multifocal diffractive intraocular lenses in cataract surgery, preliminary report. Klin Oczna 2006; 108:186-190.

  12. Blaylock JF, Si Z, Vickers C. Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lens. J Cataract Refract Surg 2006; 32:1464-1473.

  13. Chiam PJT, Chan JH, Aggarwal RK, Kasaby S. ReSTOR intraocular lens implantation in cataract surgery: Quality of vision. J Cataract Refract Surgery 2006; 32:1459-1463.

  14. Souza CE, Muccioli C, Soriano ES y cols. Visual performance of Acrysof ReSTOR apodized diffractive IOL: a prospective comparative trial. Am J Ophthalmol 2006; 141:827-832.




2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

Rev Mex Oftalmol. 2008;82