medigraphic.com
SPANISH

Revista Cubana de Oftalmología

ISSN 1561-3070 (Electronic)
  • Contents
  • View Archive
  • Information
    • General Information        
    • Directory
  • Publish
    • Instructions for authors        
  • medigraphic.com
    • Home
    • Journals index            
    • Register / Login
  • Mi perfil

2012, Number s1

<< Back Next >>

Rev Cub Oftal 2012; 25 (s1)

Needle review of the filtering bleb as an alternative in the treatment of patients undergoing trabeculectomy

Arzuaga HE, Fumero GF, González PS, Batista PM
Full text How to cite this article

Language: Spanish
References: 28
Page:
PDF size: 62.49 Kb.


Key words:

encapsulated blebs, filtering bleb, needle, failing bleb, mitomycin C, 5-fluorouracil.

ABSTRACT

Trabeculectomy is usually a successful procedure to reduce intraocular pressure in glaucoma patients. However, the failure of the filtering bleb can occur, leading to increased intraocular pressure and to a further medical or surgical intervention. A literature review on transconjunctival cystotomy, with or without the use of mitomycin C or 5-fluorouracil, was made. It was demonstrated that this method is minimally invasive with few complications, effective, easy-to-apply and inexpensive to restore aqueous drainage and lowering intraocular pressure.


REFERENCES

  1. Durak I, Ozbek Z, Yaman A, Soylev M, Cingil G. The role of needle revision and 5-fluorouracil application over the filtration site in the management of bleb failure after trabeculectomy: a prospective study. Doc Ophthalmol 2003;106(2):189-93.

  2. Ruderman JM. Revising the failing filtration bleb. Techniques in Ophthalmology 2005;3(3):133-7.

  3. Arosemena A, Ayala RS. Steps for saving failing blebs after trabeculectomy. [Internet] USA: Ocular Surgery News; 2004 [citado 1 feb 2012]. Disponible en: http://www.healio.com/ophthalmology/glaucoma/news/print/ocular-surgery-news/%7B050a94fe-6f99-47df-aef8-5cbe4bc7c1f5%7D/steps-for-saving-failing-blebs-after-trabeculectomy

  4. Fine LC, Chen TC, Grosskreutz CL, Pasquale LR. Management and prevention of thin, cystic blebs. Int Ophthalmol Clin. 2004;44(1):29-42.

  5. Perucho-Martínez S, Gutiérrez-Díaz E, Montero-Rodríguez, Mencía-Gutiérrez E, Lago-Llinás M. Repermeabilización mediante revisión con aguja de ampollas de filtración con fracaso tardío tras cirugía de glaucoma. Arch Soc Esp Oftalmol. 2006;81(9):517-22.

  6. Güerri N, Calvo P. Actualización del tratamiento de las ampollas encapsuladas postrabeculectomía. Arch Soc Esp Oftalmol. 2011;86(6):173-5.

  7. Camejo L, Noecker RJ. Managing failing blebs. [Internet] USA: Ophthalmology Management; 2007 [citado 1 feb 2012]. Disponible en: http://www.ophthalmologymanagement.com/articleviewer.aspx?articleid=101162

  8. Ewing RH, Stamper RL. Needle revision with and without 5-FU for the treatment of failed filtering blebs. Am J Ophthalmol. 1990;110(3):254-9.

  9. Shin DH, Juzych MS, Khatana AK, Swendris RP, Parrow KA. Needling revision of failed filtering blebs with adjunctive 5-fluorouracil. Ophthalmic Surg. 1993;24(4):242-8.

  10. Mardelli PG, Lederer CM, Murray PL, Pastor SA, Hassanein KM. Slit-lamp needle revision of failed filtering blebs using mitomycin C. Ophthalmology. 1996;103(11):1946-55.

  11. Shin DH, Kim YY, Ginde SY, Kim PH, Eliassi-Rad B, Khatana AK, et al. Risk factors for failure of 5-fluorouracil needling revision for failed conjunctival filtration blebs. Am J Ophthalmol. 2001;132(6):875-80.

  12. Broadway DC, Bloom PA, Bunce C, Thiagarajan M, Khaw PT. Needle revision of failing and failed trabeculectomy blebs with adjunctive 5-fluorouracil: survival analysis. Ophthalmology. 2004;111(4):665-73.

  13. Gutiérrez-Ortiz C, Cabarga C, Teus MA. Prospective evaluation of preoperative factors associated with successful mitomycin C needling of failed filtration blebs. J Glaucoma. 2006;15(2):98-102.

  14. Feldman RM, Tabet RR. Needle revision of filtering blebs. J Glaucoma. 2008;17(7):594-600.

  15. Hung JW, Bellows AR. Bleb Revision. En: Chen TC, editor. Surgical Techniques in Ophthalmology: Glaucoma Surgery. Philadelphia: Saunders Elsevier; 2008. p. 43-53.

  16. Shetty RK, Wartluft L, Moster MR. Slit-lamp needle revision of failed filtering blebs using high-dose mitomycin C. J Glaucoma. 2005;14(1):526.

  17. Iwach AG, Delgado MF, Novack GD, Nguyen N, Wong PC. Transconjunctival mitomycin-C in needle revisions of failing filtering blebs. Ophthalmology. 2003;110(4):73442.

  18. Anand N, Khan A. Long-term outcomes of needle revision of trabeculectomy blebs with mitomycin c and 5-fluorouracil: a comparative safety and efficacy report. J Glaucoma. 2009;18(7):51320.

  19. González Rodríguez MJ. I Curso teórico práctico de cirugía filtrante no perforante en glaucoma. [Internet]. Vigo: Centro de Cirugía de Mínima Invasión Jesús Usón Cáceres; 2008 [4 feb 2012]. Disponible en: http://www.ccmijesususon.com/es/noticias/141-i-curso-teo-prico-de-cirugfiltrante-no-perforante-en-glaucoma.html

  20. Zarei R, Shahhosseini S, Faragee-Oskouee G, Shokoh A.R, Hamzehdoost K. Needle revision with mitomicyn-C in encapsulated blebs. Acta Medica Iranica. 2008;46(4):295-8.

  21. Ghoneim EM, Abd El Hameed M. Needling augmented with topical application of mitomycin C for management of bleb failure. J Glaucoma. 2011;20(8):528-32.

  22. Eid TM, Spaeth GL. The glaucoma. 2nd ed. Philadelphia: Lippincott, Williams & Wilkins; 2000. p. 285-6.

  23. Kapasi MS, Birt CM, The efficacy of 5-fluorouracil bleb needling performed 1 year or more postrabeculectomy: a retrospective study, J Glaucoma. 2009;18(2):1448.

  24. Hawkins AS, Flanagan JK, Brown SV. Predictors for success of needle revision of failing filtration blebs. Ophthalmology 2002;109(4):781-5.

  25. Ophir A, Wasserman D. 5-Fluorouracil-needling and paracentesis through the failing filtering bleb. Ophthalmic Surg Lasers 2002;33(2):109-16.

  26. Palejwala N, Ichhpujani P, Fakhraie G, Myers JS, Moster MR, Katz LJ. Single needle revision of failing filtration blebs: a retrospective comparative case series with 5-fluorouracil and mitomycin. Eur J Ophthalmol. 2010;20(6):1026-34.

  27. Tham CC, Li FC, Leung DY, Kwong YY, Yick DW, Chi CC, et al. Intrableb triamcinolone acetonide injection after bleb-forming filtration surgery: a pilot study. Eye. 2006;20(12):1484-6.

  28. Kahook MY, Schuman JS, Noecker RJ. Needle bleb revision of encapsulated filtering bleb with bevacizumab. Ophthalmic Surg Lasers Imaging. 2006;37(2):148-50.




2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

Rev Cub Oftal. 2012;25