Cemented polyethylene insert in a well fixed Total knee replacement. Case report

García-Dobarganes BFE, Negrete-Corona J, Díaz-Tovar AA
Full text How to cite this article

Language: Spanish
References: 30
Page: 259-263
PDF size: 320.35 Kb.


Key words:

Knee, prosthesis, instability, revision, cement, tibial component.

ABSTRACT

We present the case of a 94 years- old patient, which was operated 14 years ago of a right total knee replacement for osteoarthritis, actually she suffers of pain and instability; her X ray shown polyethylene wear without loosening of the metal components. The polyethylene insert is not manufactured anymore so we decided cement a new polyethylene insert on the native tibial baseplate. The two years follow up show us a patient asymptomatic, good function and no radiolucencies on the tibial component. We only found a similar case report in Madrid and we believed that this decision, taken from total hip revisions, will succeed.


REFERENCES

  1. Lavernia CJ, Cardona D, Alcerro JC: Polietileno. Acta Ortop Mex. 2010; 24(3): 197-204.

  2. Heisel C, Silva M, Schmalzried TP: Bearing surface options for total hip replacement in young patients. Instr Course Lect. 2004; 53: 49-65.

  3. Schmalzried TP, Callaghan JJ: Wear in total hip and knee replacements. J Bone Joint Surg Am. 1999; 81(1): 115-36.

  4. Lara-Cotassio G, Castañeda-Galeno SA: Causas de reemplazo total de rodilla fallido. Rev Col de Or Tra. 2009; 23(2): 98-102.

  5. Lonner JH, Lotke PA: Aseptic complications after total knee arthroplasty. J Am Acad Orthop Surg. 1999; 7(5): 311-24.

  6. Bliss DG, McBride GG: Infected total knee arthroplasties. Clin Orthop Relat Res. 1985; (199): 207-14.

  7. Austin MS, Sharkey P, Hozack W, Rothman R: Knee failure mechanisms after total knee arthroplasty. Tech Knee Surg. 2004; 3(1): 55-9.

  8. Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM: Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002; (404): 7-13.

  9. Ranawat CS, Luessenhop CP, Rodriguez JA: The press-fit condylar modular total knee system. Four-to-six-year results with a posterior-cruciate-substituting design. J Bone Joint Surg Am. 1997; 79(3): 342-8.

  10. Feng EL, Stulberg SD, Wixson RL: Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. Clin Orthop Relat Res. 1994; (299): 60-71.

  11. Hirakawa K, Bauer TW, Yamaguchi M, Stulberg BN, Wilde AH: Relationship between wear debris particles and polyethylene surface damage in primary total knee arthroplasty. J Arthroplasty. 1999; 14(2): 165-71.

  12. Maloney W: The revision acetabulum: dealing with bone loss: socket retention: staying in place. Orthopedics. 2000; 23(9): 965-6.

  13. Álvarez-González P, Berjón-Rufes J, Usoz-Irada I: Recambio acetabular. Cementación de núcleo de polietileno sobre cotilo metálico previo no cementado y bien integrado (tres casos). Rev Esp Cir Ortop Traumatol. 2005; 49(3): 193-7.

  14. Bidolegui FM, Pereira S, Lugones A, Pereira H, Vindver G: Revisión acetabular con conservación del componente metálico osteointegrado y cementado de un componente de polietileno: Reporte de una serie de 40 casos. Rev Asoc Argent Ortop Traumatol. 2013; 78(4): 190-8.

  15. Springer BD, Hanssen AD, Lewallen DG: Cementation of an acetabular liner into a well-fixed acetabular shell during revision total hip arthroplasty. J Arthroplasty. 2003; 18(7 Suppl 1): 126-30.

  16. Callaghan JJ, Parvizi J, Novak CC, Bremner B, Shrader W, Lewallen DG, et al: A constrained liner cemented into a secure cementless acetabular shell. J Bone Joint Surg Am. 2004; 86-A(10): 2206-11.

  17. Sanjuan-Cerveró R, Jiménez-Honrado PJ, Gil-Monzó ER, Sánchez-Rodríguez RJ, Fenollosa-Gómez J: Biomecánica de las prótesis de rodilla. Patología del Aparato Locomotor. 2005; 3(4): 242-59.

  18. Cheng K, Pruitt L, Zaloudek C, Ries MD: Osteolysis caused by tibial component debonding in total knee arthroplasty. Clin Orthop Relat Res. 2006; 443: 333-6.

  19. Chiu YS, Chen WM, Huang CK, Chiang CC, Chen TH: Fracture of the polyethylene tibial post in a NexGen posterior-stabilized knee prosthesis. J Arthroplasty. 2004; 19(8): 1045-9.

  20. Clarke HD, Math KR, Scuderi GR: Polyethylene post failure in posterior stabilized total knee arthroplasty. J Arthroplasty. 2004; 19(5): 652-7.

  21. Majewski M, Weining G, Friederich NF: Posterior femoral impingement causing polyethylene failure in total knee arthroplasty. J Arthroplasty. 2002; 17(4): 524-6.

  22. Mariconda M, Lotti G, Milano C: Fracture of posterior-stablized tibial insert in a Genesis knee prosthesis. J Arthroplasty. 2000; 15(4): 529-30.

  23. Mestha P, Shenava Y, D’Arcy JC: Fracture of the polyethylene tibial post in posterior stabilized (Insall Burstein II) total knee arthroplasty. J Arthroplasty. 2000; 15(6): 814-5.

  24. Ng TP, Chiu KY: Recurrent dislocation of total knee arthroplasty: an unusual cause. J Arthroplasty. 2003; 18(8): 1067-70.

  25. Niki Y, Matsumoto H, Otani T, Yoshimine F, Inokuchi W, Morisue H: Gigantic popliteal synovial cyst caused by wear particles after total knee arthroplasty. J Arthroplasty. 2003; 18(8): 1071-5.

  26. Poulter RJ, Ashworth MJ: A case of dissociation of polyethylene from its metal baseplate in a “one piece” compression-moulded AGC tibial component. Knee. 2005; 12(3): 243-4.

  27. Sands KC, Silver JW: Fracture of the polyethylene tibial post in a posterior stabilized PFC total knee arthroplasty. Orthopedics. 2005; 28(10): 1203-4.

  28. Tuoheti Y, Watanabe W, Itoi E: Anterior dislocation after total knee arthroplasty: a case report. J Orthop Sci. 2004; 9(6): 643-5.

  29. Canillas del Rey FM, Nieto-López D, Carballo-Vázquez F, Sanjurjo-Navarro J: Recambio de platillo de polietileno en prótesis de rodilla integrada. A propósito de una caso. Rev Esp Cir Osteoartic. 2006, 41(227): 142-5.

  30. Furnes O, Espehaug B, Lie SA, Vollset SE, Engesaeter LB, Havelin LI: Early failures among 7,174 primary total knee replacements: a follow-up study from the Norwegian Arthroplasty Register 1994-2000. Acta Orthop Scand. 2002; 73(2): 117-29.




2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

Acta Ortop Mex. 2016 Sep-Oct;30