medigraphic.com
SPANISH

Cardiovascular and Metabolic Science

ISSN 2954-3835 (Electronic)
ISSN 2683-2828 (Print)
Antes Revista Mexicana de Cardiología

Ver Revista Mexicana de Cardiología


  • Contents
  • View Archive
  • Information
    • General Information        
    • Directory
  • Publish
    • Instructions for authors        
    • Send manuscript
  • medigraphic.com
    • Home
    • Journals index            
    • Register / Login
  • Mi perfil

2020, Number 1

Next >>

Cardiovasc Metab Sci 2020; 31 (1)

Radiofrequency catheter ablation of cardiac arrhythmias using only three-dimentional mapping systems

Robledo‑Nolasco R, Leal‑Díaz JR
Full text How to cite this article 10.35366/93256

DOI

DOI: 10.35366/93256
URL: https://dx.doi.org/10.35366/93256

Language: English
References: 18
Page: 4-8
PDF size: 825.14 Kb.


Key words:

Catheter ablation, cardiac arrhythmias, without fluoroscopy, three-dimensional mapping.

ABSTRACT

The largest number of radiofrequency catheter ablation (RCA) procedures are performed with the help of X-rays. Ionizing radiation affects both, the patient and the electrophysiologist. Today it is a priority to reduce exposure to X-rays and this is possible with new technologies and techniques for RCA. Objectives: The objective of this report is to demonstrate the feasibility and safety of performing RCA of conventional and complex cardiac arrhythmias (CA) without using X-rays in a single center. Material and methods: Patients with different CA and with indication of RCA were included. All had an echocardiogram and the antiarrhythmic drugs were suspended 5 half-lives before the procedure. Two three-dimensional mapping systems were used. First a catheter was advanced to draw the path of the access vessels and then the cardiac cavities were reconstructed and the origin of the arrhythmia was located. RCA with conventional parameters were performed. Results: We included 14 patients with mean age of 46.4 ± 16.9 years, 7 (50%) women, 2 (14.3%) had heart failure. There were 11 (78.6%) common and 3 (21.4%) complex arrhythmias. In 10 (71.4%) patients, the Carto 3 system was used and in the rest the Ensite system. A mean of 334 ± 335 mapping points were performed, an irrigated catheter was used in 12 (85.7%) patients, 50 ± 82 ablation applications were performed, the duration of the procedure was 100 ± 24 minutes and 13 (92.8%) of the procedures were successful. No X-rays were used and there were no complications. Conclusions: It is feasible and safe to perform RCA of conventional or complex CA with a three-dimensional mapping system, without using X-rays and with 92.8% success rate.


REFERENCES

  1. Cappato R, Kuck KH. Catheter ablation in the year 2000. Curr Opin Cardiol. 2000; 15: 29-40.

  2. Giaccardi M, Del Rosso A, Guarnaccia V, Ballo P, Mascia G, Chiodi L et al. Near-zero x-ray in arrhythmia ablation using a 3-dimensional electroanatomic mapping system: a multicenter experience. Heart Rhythm. 2016; 13: 150-156.

  3. Perisinakis K, Damilakis J, Theocharopoulos N, Manios E, Vardas P, Gourtsoyiannis N. Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures. Circulation. 2001; 104: 58-62.

  4. Smith IR, Rivers JT, Hayes J, Stafford W, Codd C. Reassessment of radiation risks from electrophysiology procedures compared to coronary angiography. Heart Lung Circ. 2009; 18: 191-199.

  5. Ferguson JD, Helms A, Mangrum M, Mahapatra S, Mason P, Bilchick K et al. Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping. Circ Arrhythm Electrophysiol. 2009; 2: 611-619.

  6. Koutalas E, Rolf S, Dinov B, Richter S, Arya A, Bollmann A et al. Contemporary mapping techniques of complex cardiac arrhythmias identifying and modifying the arrhythmogenic substrate. Arrhythm Electrophysiol Rev. 2015; 4 (1): 19-27.

  7. Earley MJ, Showkathali R, Alzetani M, Kistler PM, Gupta D, Abrams DJ et al. Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial. Eur Heart J. 2006; 27 (10): 1223-1229.

  8. Kottkamp H, Hugl B, Krauss B, Wetzel U, Fleck A, Schuler G et al. Electromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter: a prospective randomized study. Circulation. 2000; 102 (17): 2082-2086.

  9. Kesek M, Wallenius N, Ronn F, Hoglund N, Jensen S. Reduction of fluoroscopy duration in radiofrequency ablation obtained by the use of a non-fluoroscopic catheter navigation system. Europace. 2006; 8 (12): 1027-1030.

  10. Picano E, Vañó E. The radiation issue in cardiology: the time for action is now. Cardiovasc Ultrasound. 2011; 9: 35.

  11. McFadden SL, Mooney RB, Shepperd PH. X-ray dose and associated risks from radiofrequency catheter ablation procedures. Br J Radiol. 2002; 75: 253-265.

  12. Perisinakis KP, Damilakis J, Theocharopoulos N, Manions E, Vardas P, Gourtsoyiannis N. Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures. Circulation. 2001; 104: 58-62.

  13. Anselmino M, Sillano D, Casolati D, Ferraris F, Scaglione M, Gaita F. A new electrophysiology era. J Cardiovasc Med. 2013; 14 (3): 221-227.

  14. Stec S, Sledz J, Mazij M, Ras M, Ludwik B, Chrabaszcz M et al. Feasibility of implementation of a “simplified, no-X-ray, no-lead apron, two-catheter approach” for ablation of supraventricular arrhythmias in children and adults. J Cardiovasc Electrophysiol. 2014; 25: 866-874.

  15. Damilakis J, Theocharopoulos N, Perisinakis K, Manios E, Dimitriou P, Vardas P et al. Conceptus radiation dose and risk from cardiac catheter ablation procedures. Circulation. 2001; 104: 893-897.

  16. Scaglione M, Ebrille E, Di Clemente F, Gaita F. Catheter ablation of atrial fibrillation without radiation exposure using a 3d mapping system. J Atr Fibrillation. 2015; 7: 56-62.

  17. Sadek MM, Ramirez D, Nery PB, Golian M, Redpath CJ, Nair GM et al. Completely nonfluoroscopic catheter ablation of left atrial arrhythmias and ventricular tachycardia. J Cardiovasc Electrophysiol. 2019; 30: 78-88.

  18. Lyan E, Tsyganov A, Abdrahmanov A, Morozov A, Bakytzhanuly A, Tursunbekov A et al. Nonfluoroscopic catheter ablation of paroxysmal atrial fibrillation. Pacing Clin Electrophysiol. 2018; 4: 611-619.




2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

Cardiovasc Metab Sci . 2020;31