Acta Ortopédica Mexicana

Martínez-Padilla LA, Peñafort-García JA
Radiographic and functional results of plate of oxnamic ram compression versus plate of compression bolted in radial and cubital fractures
Acta Ortop Mex 2007; 21 (6)

Language: Español
References: 46
Page: 306-312
PDF: 254.39 Kb.

[Fulltext - PDF]

ABSTRACT

Objective: To determine if there are statistically significant differences in radiographic and functional outcome in postoperative patients with DCP (dynamic compression plate) vs. LCP (locking compression plate) in fractures radial and/or ulnar shaft. Material and methods: Quasi-experimental, observational, longitudinal, comparative and prospective study, with patients surgically stabilized using the implants mentioned before with diaphyseal forearm fractures in the Balbuena General Hospital from September 1st to February 28th of 2005, with 2 years of follow-up. Results: 22 patients were surgically stabilized with dynamic compression plate and 11 with locking compression plate, gender male in 88%, predominantly in 3rd life decade, earlier consolidation in the group of locking compression plate but with greater functional limitation. The differences decreased after 3 months and 6 months of clinical follow up, with no statistically significant differences at 2 years of follow-up. Conclusions: Although there are differences at the 1st and 3rd months of postoperative period, attributable to stability provided by each one of the implants, the beginning of mobilization and the soft-tissue handling, there are no statistically significant differences in the preliminary results at 6 months and finally at 2 years of follow-up. We consider that implants in study, even though of acting in a relatively different way, both of them are excellent alternatives of treatment in patients with forearm shaft fractures.


Key words: radius fracture, ulnar fracture, dynamic plate, compression plate, comparative study.


REFERENCES

  1. Perren SM: Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg (Br) 2002; 84B: 1093-1110.

  2. Perren SM, Russenberger M, Steinmann S, et al: The dynamic compression plate. Act Orthop Scand 1969; 31(Suppl 125): 31-41.

  3. Anderson LD, Meyer FN: Fractures of the shafts of the radius and ulna. In: Rockwood and Green’s Fractures in adults, ed by Rockwood CA, Green DP, Bucholz RW. Philadelphia, JB Lippincott, 1991: 679-737.

  4. Anderson LD, Sisk TD, Tooms RD, Park WI III: Compression-plate fixation in acute diaphyseal fractures of radius and ulna. J Bone Joint Surg (Am) 1975; 57: 287-97.

  5. Chapman MW, Gordon JE, Zissimos AG: Compression-plate fixation of acute fractures of the diaphysis of the radius and ulna. J Bone Joint Surg (Am) 1989; 71: 159-69.

  6. Dodge HS, Cady GW: Treatment of fractures of the radius and ulna with compression plates. J Bone Joint Surg (Am) 1972; 54: 1167-76.

  7. Grace TG, Eversmann WW Jr: Forearm fractures: treatment by rigid fixation and early motion. J Bone Joint Surg (Am) 1980; 62(3): 433-8.

  8. Kellam JF, Jupiter JB: Diaphyseal fractures of the forearm. In: Skeletal Trauma; Fractures, Dislocations, and Ligamentous Injuries, ed by Browner BD, Jupiter JB, Levine AM, Trafton PG. Philadelphia, WB Saunders, 1992: 1095-1124.

  9. Moed BR, Kellam JF, Foster RJ, Tile M, Hansen ST: Immediate internal fixation of open fractures of the diaphysis on the forearm. J Bone Joint Surg (Am) 1986; 68: 1008-17.

  10. Hertel R, Pisan M, Lambert S, Ballmer FT: Plate osteosynthesis of diaphyseal fractures of the radius and ulna. Injury 1996; 27(8): 545-8.

  11. Field JR, Hearn TC, Caldwell CB: The influence of screw torque, object radius of curvature, mode of bone plate application and bone plate design on bone-plate interface mechanics. Injury 1998; 29(3): 233-41.

  12. Perren SM, Klaue K, Pohler O, et al: The limited contact dynamic compression plate (LC-DCP). Arch Orthop Trauma Surg 1990; 109: 304.

  13. Jacobs RR, Rahn BA, Perren SM: Effects of plates on cortical bone perfusion. J Trauma 1981; 21: 910.

  14. Luethi U, Dueland T, Rahn BA: Relationship between plate-bone contact area and blood supply in internal fixation. J Biomech 1980; 13: 779.

  15. Swiontkowski MF, Senft D, Taylor S, et al: Plate design has an effect on cortical bone perfusion. Trans Orthop Res Soc 1991; 15:.

  16. Lobo LJ, Shekhman M, Mishra S, et al: Effect of cortical contact area on biomechanical properties of LC-DCP plates for fixation of transverse fractures. In: Proceedings of the 68th AAOS 2001: 339.

  17. Schatzker J. Changes in the AO/ASIF principles and methods. Injury 1995; 26(Suppl 2): SB51-56.

  18. Ganz R, Mast J, Weber BG, et al: Clinical aspects of «biological» plating. Injury 1991; 22: 4-5.

  19. Leunig M, Hertel R, Siebenrock KA, et al: The evolution of indirect reduction techniques for the treatment of fractures. Clin Orthop 2000; 375: 7-14.

  20. Field JR, Edmonds-Wilson R, Stanley RM: An evaluation of interface contact profiles in two low contact bone plates. Injury 2004; 35: 551-6.

  21. Perren SM, Buchanan JS: Basics concepts relevant to the design and development of the point-contact fixator (PC-Fix). Injury 1995; 26(Suppl 2) SB1-4.

  22. Miclau T, Remiger A, Tepic S, et al: A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate and the point-contact fixator. J Orthop Res 1995; 9: 170.

  23. Frigg R: Locking Compression Plate (LCP): an osteosynthesis plate based on the dynamic compression plate and the point-contact fixator (PC-Fix). Injury 2001; 322: SB63-66.

  24. Klaue K: Principles of plate and screw osteosynthesis. In: Oxford Textbook of Orthopaedics and Trauma, ed by Bulstrode C, Buckwalter J, Carr A, Oxford University Press, 2002: 1697-1710.

  25. Baumgaertel F, Buhl M, Rahn BA: Fracture healing in biological plate osteosynthesis. Injury 1998; 29: C3-6.

  26. Fernandez Dell’Oca AA, Tepic S, Frigg R, et al: Treating forearm fractures using an internal fixator: a prospective study. Clin Orthop 2001; 389: 196-205.

  27. Leung F, Chow SP: A prospective, randomized trial comparing the limited contact dynamic compression plate with the point contact fixator for forearm fractures. J Bone Joint Surg (Am) 2003; 85(12): 2343-8.

  28. Tepic S, Perren SM: The biomechanics of the PC-Fix internal fixator. Injury 1995; 26(Suppl 2): SB5-10.

  29. Alexander AH, Cabaud HE, Johnston JO, Lichtman DM: Compression plate position: extraperiosteal or subperiosteal? Clin Orthop 1983; 175: 280-5.

  30. Müller ME, Allgöwer M, Schneider R, et al: Manual of Internal Fixation. Techniques Recommended by the AO Group. 3rd ed Berlin, Springer-Verlag, 1991.

  31. Sanders R, Haidukewych GJ, Milne T, Dennis J, Latta LL: Minimal versus maximal plate fixation of the ulna: the biomechanical effect of number of screws and plate length. JOT 2002; 16(3): 166-71.

  32. Tornkvist H, Hearn TC, Schatzker J: The strength of plate fixation in relation to the number and spacing of bone screws. J Orthop Trauma 1996; 10: 204-8.

  33. Gustilo RB, Anderson JT: Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones. Retrospective and prospective analyses. J Bone Joint Surg (Am) 1976; 58: 453-8.

  34. Woo SLY, Lothringer KS, Akeson WH: Less rigid internal fixation plates: historical perspectives and new concepts. J Orthop Res 1984; 1: 431-49.

  35. Krettek C: Foreword: concepts of minimally invasive plate osteosynthesis. Injury 1997; 28: A1-2.

  36. Rüedi TP, Perren SM, Frigg R, Frenk A: Locking Compression Plate. AO Teaching Series ed by Wagner M, Switzerland, 2002.

  37. Solanki PV, Mulgaonkar KP, Rao SA: Effect of early mobilization on grip strength, pinch strength and work of hand muscles in cases of closed diaphyseal fracture radius-ulna treated with dynamic compression plating. J Postgrad Med 2000; 46: 84-7.

  38. Langkamer VG, Ackroyd CE: Internal fixation of forearm fractures in the 1980s: lessons to be learnt. Injury 1991; 22: 97-102.

  39. Ross ERS, Gourevitch D, Hastings GW, Wynn-Jones CE, Ali S: Retrospective analysis of plate fixation of diaphyseal fractures of the forearm bones. Injury 1989; 20: 211-4.

  40. Wright RR, Schmeling GJ, Schwab JP: The necessity of acute bone grafting in diaphyseal forearm fractures: a retrospective review. JOT 1997; 11(4): 288-94.

  41. Burwell HN, Charnley AD: Treatment of forearm fractures in adults with particular reference to plate fixation. J Bone Joint Surg (Br) 1964; 46: 404-25.

  42. Hadden WA, Reschauer R, Seggl W: Results of AO plate fixation of forearm shaft fractures in adults. Injury 1985; 15: 44-52.

  43. Gómez AOA, Bocanegra SN, Suárez FR: Fracturas abiertas diafisarias de antebrazo por armas de guerra: Osteosíntesis por abordaje limitado. Rev Col Ort Traum 2001; 15(1):.

  44. Gustilo RB, Anderson JT: Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones. Retrospective and prospective analyses. J Bone Joint Surg (Am) 1976; 58: 453-8.

  45. Gustilo RB, Mendoza RM, Williams DN: Problems in the management of type III (severe) open fractures: a new classification of type III open fractures. J Trauma 1984; 24: 742-6.

  46. Hertel R, Eijer H, Meisser A, Hauke C, Perren SM: Biomechanical and biological considerations relating to the clinical use of the Point-Contact Fixator. Evaluation of the device handling test in the treatment of diaphyseal fractures of the radius and/or ulna. Injury 2001; 32(Suppl 2): SB10-14.