medigraphic.com
SPANISH

Archivos de Cardiología de México

  • Contents
  • View Archive
  • Information
    • General Information        
    • Directory
  • Publish
    • Instructions for authors        
  • medigraphic.com
    • Home
    • Journals index            
    • Register / Login
  • Mi perfil

2004, Number 2

<< Back Next >>

Arch Cardiol Mex 2004; 74 (2)

Intracardiac echocardiography (ICE) in the operating room as a support measure in the evaluation of immediate surgical results in congenital cardiopathies

Erdmenger OJ, Vázquez-Antona C, Becerra BR,Ramírez MS, Soulé M, Romero-Cárdenas A, Roldán FJ, Buendía HA, Vargas-Barrón J
Full text How to cite this article

Language: Spanish
References: 5
Page: 126-130
PDF size: 78.79 Kb.


Key words:

Echocardiography, Intracardiac echocardiography, Congenital heart disease, Cardiovascular surgery.

ABSTRACT

The utilization of intracardiac echocardiography (ICE) is a recent alternative in the control of procedures in the Cath Lab. In this paper we presents the results of a pilot study, in 10 patients submitted to total correction of its congenital heart disease, in who the analysis of the surgical results was done in base to the application of intracardiac echocardiography in operations room. In all the patients it was possible to obtain adequate images with ICE, there was a case false negative, a Total anomalous return Pulmonary Veins, in whom there not indentified a obstruction in right pulmonary veins flow. We conclude that ICE is a good alternative in the evaluation of surgical results.


REFERENCES

  1. Bruce CJ, Packer DL, Belohlavek M, Seward JB: Intracardiac Echocardiography: newest technology. J Am Soc Echocardiography 2000; 13(8): 788-95.

  2. Chu E, Kalman JM, Kwasman MA, Jue JC, Fitzgerald PJ, Epstein LM, et al: Intracardiac echocardiography during radiofrequency catheter ablation of cardiac arrhythmias in humans. J Am Coll Cardiol 1994; 24: 1351-7.

  3. Mullen MJ, Dias BF, Walker F, Siu SC, Benson LN, McLaughlin PR: Intracardiac echocardiography guided device closure of atria septal defects. J Am Coll Cardiol 2003; 41: 285-92.

  4. Salem MI, Makaryus AN, kort S, Chung E, Marchant D, Ong L, Mangion J: Intracardiac echocardiography using the AcuNav ultrasound catheter during percutaneous balloon mitral valvuloplasty. J Am Soc Echocardiogr 2002; 15: 1533-7.

  5. Schwartz SL, Gillam LD, Weintraub AR, Sanzobrino BW, Hirst JA, Fisher JP, et al: Intracardiac echocardiography in humans using a small-sized low Frequency (12.5 MHz) ultrasound catheter. Methods, imagin planes and clinical experience. J Am Coll Cardiol 1993; 21(1): 19-98.




2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

Arch Cardiol Mex. 2004;74