2012, Number 5
<< Back Next >>
Rev ADM 2012; 69 (5)
An Analysis of the surface and cementation of titanium posts.
Ontiveros GA, Cobos HE, Espinosa TND, Espinosa TA
Language: Spanish
References: 22
Page: 226-232
PDF size: 191.94 Kb.
ABSTRACT
The present study was designed to determine the
transportation of the root canal system induced by the
MTWO rotary instrumentation system and the
balanced-force technique. Both systems were
measured using the angular measuring of
transportation technique. The results obtained by
comparing both systems showed no significant
statistical differences.
REFERENCES
Balandrano PF, Hilú R, Pérez A. Evaluación de la conformación de conductos cur vos simulados con los sistemas ProTaper,Universal, Light Speed Extra y Mtwo. Endodoncia. 2009; 27 (04):175-180.
Ponti TM, McDonald NJ, Kuttler S, Strassler HE, Dumsha TC. Canal-centering ability of two rotatory file systems. J.of Endod. 2002; 28 (04): 283-286.
Boada C, Moré A. Comparación in vitro de 2 sistemas rotatorios de instrumentación en endodoncia (Protaper y k3) en conductos curvos simulados. Revista científica. 2005; 11 (2): 57-64.
Ankrum MT, Hartwell GR, Truitt JE. K3 Endo, Protaper and ProFile Systems: Breakage and distortion in several curved roots of molars. JOE. 2004; 30 (04): 234-7.
Booth JR, Scheetz JP, Lemons JE, Eleazer PD. A comparison of torque required to fracture three different nickel- titanium rotator instruments around curves of the same angle but of different radius when bound at the tip. J. of Endod. 2003; 29 (01): 55-57.
Kum K, Spängberg L, Cha BY, Young J, Seung-Jong J, Chan-Young L. Shaping ability of three profile rotary instrumentation techniques in simulated resin root canals. J. of Endod. 2000; 26 (12): 719-723.
Jovel J, Sabillon I. Principios básicos en el manejo de conductos c u r v o s y e s t r e c h o s . D i s p o n i b l e e n : http://www.javeriana.edu.co/academiapgendodoncia/art_revisio n/revision_2006/i_a_revision43.html
Gunday M, Sazak H, Garip Y. A Comparative study of three different root canal curvature measurement techniques and measuring the canal access Angle in curved canals. J of Endod. 2005; 31 (11): 796-798.
Herrera DA, Duran MJ, Guzmán BA. Evaluación de la transportación y ensanchamiento in-vitro del sistema Pro-taper. Rev A.D.M. 2004; 61(1):5-13.
Frajlich S. Endodoncia: Preparación quirúrgica. Disponible en: http://www.dentsplyargentina.com.ar/Endodoncia%20Preparaci on.pdf
Canalda SC, Brau AE. Endodoncia. Técnicas clínicas y bases científicas. 2ª ed. Elsevier-Masson 2006. pp. 163-193.
Leonardo MR. Endodoncia, tratamiento de conductos radiculares. Principios técnicos y biológicos. Ed. Latinoamericana, Volumen 1. 2005. p. 9,322-325,541.
Leonardo MR, Leonardo R. Sistemas Rotatorios en Endodoncia. 1ª ed. Sao Paulo: Artes Médicas Ltda. 2002. p. 20-22.
Leonardi L, Atlas D, Raiden G. Comparación de dos métodos para evaluar la transportación apical. Acta Odontológica Venezolana. 2007; 45: 1-6.
Esposito PT, Cunningham C J. A comparison of canal preparation wich nickel-titanium and stainless steel instruments. J Endod. 1995; 21:173-6.
Espinosa, TA. Técnica de medición angular de la trasportación de los conductos radiculares. Endodoncia actual. 2006; 1(2):18-22.
Cervantes A F. Trasportación del tercio apical con lightspeed LSX y fuerzas balanceadas empelando la técnica de medición angular (estudio in vitro). Rev sanid milit. 2008; 62(2): 86-90.
Secretaria de la defensa nacional. Matemáticas para artillería. p.35
Shneider SW. A comparison of canal preparations in straight and curve root canals. Oral Surg Oral Med Oral Pathol. 1971; 32: 271-275
Zaia, AA, Randi FC, Hiroshi YG, Souza FF. A Simple Method for the Analysis of Root Canal Preparation. J of Endod. 2000; 26(03): 172-174.
Hata, GI, Vemura M, Kato AS, Imura N, Novo NF, Toda T. A comparison of shaping ability using ProFile,GT File, And Flex-R Endodontic instruments in simulated canals. J of Endod. 2002; 28 (04): 316-321
Finten de Tarallo SB. Comparación de dos técnicas de instrumentación en conductos radiculares estrechos y curvos de la raíz mesial de molares inferiores, in vitro. Endodoncia. 2009; 27 (04):181-189.