Hemoglobin A1c: A reliable and accurate test for diabetes care? A prospective study in Mexico

González-González JG, Rodríguez-Gutiérrez R, Lavalle-González FJ, González-Cantú A, Taméz-Pérez HE, González-Saldívar G, Villarreal-Pérez JZ
Full text How to cite this article

Language: English
References: 31
Page: 462-468
PDF size: 205.43 Kb.


Key words:

diabetes mellitus, hemoglobin A glycosylated, laboratory test, Mexico.

ABSTRACT

Objective. To compare the concordance correlation coefficient for HbAlc results in an in-field experience. Materials and methods. A prospective study in Monterrey, Mexico from April to August 2012 was conducted to evaluate the day-to-day clinical situation when measuring HbAlc. Blood samples from 38 consecutive patients were sent to seven local laboratories and one international reference laboratory. Results. Poor concordance was found in 4 out of 7 laboratories, moderate in 2 out of 7, and significant in just one. HbAlc values from three laboratories fluctuated more than 1% above or below the reference laboratory in more than 30% of cases, and more than 2% in 10%-20% of subjects. Conclusions. Standardized HbAlc measurement has not occurred worldwide. Physicians should be aware of this issue and be cautious of HbAlc guidelines on diabetes diagnosis or management until proper standardization programs are implemented


REFERENCES

  1. Gough S, Manley S, Stratton I, eds. In:HbA1c in diabetes. Case studies using IFCC units. Introduction. Hoboken NJ: Blackwell Publishing Ltd, 2010:1-28.

  2. Dailey G. Assessing glycemic control with self-monitoring of blood glucose and hemoglobin A1c measurements. Mayo Clin Proc 2007;82:229-236.

  3. Woo V, Shestakova MV, Orskov C, Ceriello A. Targets and tactics:the relative importance of HbA1c, fasting and postprandial plasma glucose levels to glycaemic control in type 2 diabetes. Int J Clin Pract 2008;62:12:1935-1942.

  4. Marshall SM. Standardization of HbA1c:good or bad? Nat Rev Endocrinol 2010;6:408-411.

  5. Nathan DM, Turgeon H, Regan S. Relationship between glycated haemoglobin levels and mean glucose levels over time. Diabetologia 2007;50:2239-2244

  6. The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977-986

  7. UK Prospective Diabetes Study Group. Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). Lancet 1998;352:837-853.

  8. Nathan DM, Balkau B, Bonora E, Borch-Johnsen K, Buse JB, Colagiuri S, et al. International Expert Committee report on the role of the A1C assay in the diagnosis of diabetes. Diabetes Care 2009;32:1327-1334.

  9. Bennett CM, Guo M, Dharmage SC. HbA(1c) as a screening tool for detection of type 2 diabetes:a systematic review Diabet Med 2007;24:333-343

  10. Kramer CK, Araneta MR, Barrett-Connor E. A1c and diabetes diagnosis:The rancho San Bernardo Study. Diabetes care 2010;33:101-103.

  11. Little RR, Rohlfing CL, Wiedmeyer HM, Myers GL, Sacks DB, Goldstein DE. The National Glycohemoglobin Standardization Program:a five-year progress report. Clin Chem 2001;46:1985-1992.

  12. Hoelzel W, Miedema K. Development of a reference system for the international standardization of HbA1c/glycohemoglobin determinations. Int Fed Clin Chem 1996;9:62-67

  13. GLAD working group. Recommendations for the implementation of international standardization of glycated hemoglobin in Italy. Clin Chem Lab Med 2010;48:623-626.

  14. Berg AH, Sacks DB. Haemoglobin A1c analysis in the management of patients with diabetes:from chaos to harmony. J Clin Pathol 2008;61:983-987.

  15. Consensus statement on the worldwide standardization of the hemoglobin A1c measurement:the American Diabetes Association, European Association for the Study of Diabetes, International Federation of Clinical Chemistry and Laboratory Medicine, and the International Diabetes Federation. Diabetes Care 2007;30:2399-2400.

  16. Mosca A, Goodall I, Hoshino T, Jeepson JO, John WG, Little RR et al. Global standardization of glycated hemoglobin measurement:the position of the IFCC Working Group. Clin Chem Lab Med 2007;45:1077-1080.

  17. Manley SE. Estimated average glucose derived from HbA1c (eAG):report from European Association for the Study of Diabetes (EASD), Amsterdam 2007. Diabet Med 2008;25:126-128.

  18. Leslie C. LAI. Global standardization of HbA1c. Malasyan J Pathol 2008;30:67-71

  19. Hanas R, John G. 2010 Consensus statement on the worldwide standardization of the hemoglobin A1c measurement. Diabetes Res Clin Pract 2010;90:228-230.

  20. Villalpando-Hernández S, Cruz V, Rojas R, Shamah-Levy T, Ávila MA, Gaona B, et al. Prevalence and distribution of type 2 diabetes mellitus in Mexican adult population. A probabilistic survey. Salud Publica Mex 2010, 52:19-26

  21. Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-268.

  22. Schoonjans F, Zalata A, Depuydt CE, Comhaire FH. MedCalc:a new computer program for medical statistics. Comput Methods Programs Biomed 1995:48;257-262.

  23. Inzucchi SE. Diagnosis of diabetes. N Engl J Med 2012;367:542-550.

  24. Beer KA. A1c assay emerges as the new standard diagnostic test. JAAPA 2010;23:50-51.

  25. Llanes de Torres R. Glicada para el diagnóstico de la diabetes, ¿un estándar universal? Aten Primaria 2010;42:571-576.

  26. Álvarez-García E. HbA1c, estandarización y expresión de resultados. Endocrinol Nutr 2010;57:177-181.

  27. Holmes EW, Ersahin C, Augustine GJ, Charnogursky GA, Gryzbac M, Murrell JV, et al. Analytical bias among certified methods for the measurement of hemoglobin A1c. A cause for concern? Am J Clin Pathol 2008;129:540-547.

  28. Rojano-Rodríguez E, Acosta-González RI, Bocanegra-Alonso A, Rivera- Sanchez G, Sierra-Amor RI. Desempeño de un grupo de laboratorios mexicanos en la determinación de HBA1C. Bioquimia 2007;32:91-99.

  29. Schweitzer M, Cavan DA, Ziegler R. Is HbA1c a reliable measure for assessing glycaemic control? Diabetologia 2012;55:Suppl 1:S1-S538

  30. Méndez-Chacón E, Rosero-Bixby L, Fernández-Rojas X, Barrantes- Jimenes K. Comparación de los resultados de pruebas de laboratorio seleccionadas de un estudio poblacional de adultos mayores de Costa Rica. Población y Salud en Mesoamérica 2007;5:2-15. [Accessed April 2012]. Disponible en: http://www.ccp.ucr.ac.cr/revista/.

  31. Inzucchi SE, Bergenstal RM, Buse JB, Diamant M, Ferrannini E, Nauck M. Management of hyperglycemia in type 2 diabetes:a patient-centered approach:position statement of the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD). Diabetes Care 2012;35(6):1364-1379. Epub 2012 Apr 19.




2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

salud publica mex. 2013;55