Rev Cub Oftal 2020; 33 (4)

Ex-PRESS implantation by Richard Hoffman's technique

Fumero GFY, Piloto DI, Baiocchi S, Arzuaga HE, Pérez RY
Full text How to cite this article

Language: Spanish
References: 20
Page: 1-12
PDF size: 521.98 Kb.


Key words:

glaucoma, Ex-PRESS, modified Richard Hoffman's technique.

ABSTRACT

Filtration surgery is a therapeutic option aimed at reducing intraocular pressure when there is no response to non-surgical alternatives. Filtration surgery has developed remarkably in recent years. New devices have emerged geared to achieving pressure control with minimum complications. Among them, Ex-PRESS implantation has shown to be as effective as trabeculectomy, and the technique described by Richard Hoffman provides excellent results with fewer difficulties. A case is presented of a male white 51-year-old patient with a history of glaucoma, best corrected visual acuity 100 VAR, and intraocular pressure 32 mmHg. Implantation was performed of an Ex-PRESS (model P-50)device by modified Richard Hoffman's technique associated to 0.2% mitomycin C inthe perioperative period. Two years after surgery, ocular tensions of 17 mmHg and a best corrected visual acuity of 100 VAR had been achieved.


REFERENCES

  1. Río Torres M, Fernández Argones L, Hernández Silva JR. Oftalmología. Diagnósticoy tratamiento. La Habana: Ed. Ciencias Médicas, 2017;(2):106-10.

  2. Bourne RR, Taylor HR, Flaxman SR, et al; Vision Loss Expert Group of the GlobalBurden of Disease Study. Number of people blind or visually impaired by glaucoma worldwide and in world regions 1990 - 2010: a meta-analysis. PLoS One. 2016;11(10):e0162229.

  3. Hernández Silva JR. Resultados del RACSS en Ciudad de La Habana, Cuba, 2005. RevCubana Oftalmol. 2006;19(1):5.

  4. Fernández L, Martin Y. Trabeculectomía. En: Fernández L. Glaucoma. Temasquirúrgicos. La Habana: ECIMED; 2013. p. 55-84.

  5. Khaimi MA. Canaloplasty: a minimally invasive and maximally effective glaucomatreatment. J Ophthalmol. 2015;2015:485065.

  6. Vila-Arteaga J, Vila-Mascarell E. Ordenando las técnicas quirúrgicas del glaucoma. Arch Soc Esp Oftalmol. 2014;89(8):2.

  7. Salim S. The role of the Ex-PRESS glaucoma filtration device in glaucoma surgery. Seminars in Ophthalmology. 2013;28(3):180-4.

  8. Dahan GJ, Simon B, Lafuma A. Comparación de presión intraocular con el tiempodespués de trabeculectomía estándar en un ojo e implante Ex-PRESS en el otro en pacientes con glaucoma primario de ángulo abierto bilateral. Eye. 2012;26:703-10.

  9. Sánchez Ferreiro AV, Muñoz Bellido L. Esclerostomía protegida con implant Ex-PRESS. Arch Soc Esp Oftalmol. 2013;88(8):327-30.

  10. De Feo F, Bagnis A, Bricola G, Scotto R, Traverso CE. Efficacy and safety of a steeldrainage device implanted under a scleral flap. Can J Ophthalmol. 2009;44:457-62.

  11. Ahmed I. MIGS and the FDA: what’s in a name? Ophthalmology. 2015;122(9):1737-39.

  12. Hoffman R; Crandall A; Crandall D; Bien I; Packer M; Sims A. Rev Glauc. 2016;23(4): 254-7.

  13. Maris P, Ishida K, Netland P. Comparison of trabeculectomy with ExPRESSminiature glaucoma device implanted under scleral flap. J Glauc. 2007;16:14-9.

  14. Gallego-Pinazo R, López-Sánchez E, Marín-Montiel J. Resultados posquirúrgicos enla cirugía combinada de glaucoma. Comparación del implante Express con la trabeculectomía estándar. Arch Soc Esp Oftalmol. 2009;84:293-8.

  15. Konopińska J, Deniziak M, Saeed E, Bartczak A, Zalewska R. Prospectiverandomized study comparing combined phaco-ExPress and phacotrabeculectomy in open angle glaucoma treatment: 12-Month Follow-Up. J Ophthalmol. 2015;2015:720109.

  16. Coupin A, Li Q, Riss I. Implant miniature Ex-PRESSTM placé sous unvolet scléralDans la chirurgie du glaucome á angle ouvert: étuderétrospective. J Fr Ophthalmol. 2007;30:1:18-23.

  17. Vetrugno M, Ferreri P, Sborgia C. Ex-PRESS miniature glaucoma device invitrectomized eyes. Eur J Ophthalmol. 2010;20(5):945-7.

  18. Teng CC, Radcliffe N, Huang JE, Farris E. Ex-PRESS glaucoma shunt dislocationinto the anterior chamber. J Glauc. 2008;17:687-9.

  19. Tavolato M, Babighian S, Galan A. Spontaneous extrusion of a stainless steelglaucoma drainage implant (Ex-PRESS). Eur J Ophthalmol. 2006;16(5):751-3.

  20. Ansar E. An update on implants for minimally invasive glaucoma surgery (MIGS). Ophthalmol Ther. 2017;6(2):233-41.




2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

Rev Cub Oftal. 2020;33