2022, Number 4
Relationship of the anatomical planes of the crystalline lens to the actual position of the intraocular lens
Language: Spanish
References: 32
Page: 1-19
PDF size: 338.14 Kb.
ABSTRACT
Purpose: To determine the relationship of the anatomical planes of the crystalline lens with the actual position of the intraocular lens in patients with a diagnosis of cataract seen at the Ocular Microsurgery Center of the Cuban Institute of Ophthalmology during the period January 2018 and January 2021.Methods: An observational, descriptive, prospective longitudinal study was performed in 89 eyes of 67 patients operated on for cataract with intraocular lens implantation (IOL) by phacoemulsification technique. The IOL Master 700 and the SRK/T formula were used to calculate lens power. The OCT image provided by the IOL Master 700 was used to determine the equatorial plane and central plane of the crystalline lens, as well as the actual position of the intraocular lens.
Results: The age group 60-79 years was predominant, female gender represented 53 %. Average eye size and ocular biometric measurements in standard average values were the most representative. The equatorial plane showed less difference with the actual intraocular lens position compared to the difference evidenced between the central plane and the actual lens position. The adequate position of the intraocular lens calculated in the capsular bag independent to the axial length, allowed to obtain a refractive result in correspondence to the one expected before surgery.
Conclusion: The anatomical parameters of the crystalline lens (equatorial plane, central plane) are important variables to be taken into account for the development and improvement of the formulas for the calculation of the intraocular lens.
REFERENCES
Pérez Candelaria EC, González Blanco Y, Fernández Argones L, Rodríguez Suárez B, Pedroso Llanes A, Méndez Duque de Estrada AM. Correlación entre la localización del lente intraocular, según biomicroscopía ultrasónica, y diferentes parámetros quirúrgicos en pacientes operados de catarata. Rev Cub. Oftalmol. 2010[acceso 20/02/2021];23(supl.1). Disponible en: Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762010000300003&lng=es 1.
Olguin Manríquez A, Ramos Espinoza K, Lizárraga Velarde S, Romo García E. Opacificación capsular posterior en lentes intraoculares hidrofílicos en comparación con lentes intraoculares hidrofóbicos usando imágenes de Scheimpflug. Rev Mex Oftalmol. 2016 [acceso 20/02/2021];90(2):57-64. Disponible en: Disponible en: https://www.sciencedirect.com/science/article/pii/S0187451915000876 2.
Cabañas-Lizama JM, Perdiz-Calvo L, Villanueva-Pérez G, Madrazo-Arjona A. Determinación de la posición efectiva del lente intraocular mediante tomografía de coherencia óptica y ultrabiomicroscopía. Revista Mexicana de Oftalmología. 2010 [acceso 20/02/2021];84(3):148-52. Disponible en: Disponible en: https://www.elsevier.es/es-revista-revista-mexicana-oftalmologia-321-articulo-determinacion-posicion-efectiva-del-lente-X0187451910842437 6.
Veitía Rovirosa ZA, Plá Acevedo ME, Pérez Candelaria E, Rodríguez Suárez B, Durán Vaquero R, Dueñas Moreno María de las M. Evolución de la biometría de coherencia óptica y las nuevas plataformas. Rev. Cub. Oftalmol. 2019[acceso 22/03/2021];32(2). Disponible: Disponible: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762019000200015&lng=es 8. Epub 30-Sep-2019.
Veitía Rovirosa ZA, Hernández González ME, Pérez Candelaria EC, Rodríguez Suárez B, Méndez Duque de Estrada AM, Hernández López I. Resultados del lente intraocular con la fórmula holladay 2 en pacientes con catarata. Rev. Cub de Oftalmología. 2020[acceso 24/03/2021];33(3). Disponible en: Disponible en: http://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/891/847 15.
Montero Díaz E, Serpa Valdés M, Cuan Aguilar Y, Pérez Candelaria E de la C, Hernández López I, Vidal del Castillo M. Efectividad de la biometría de inmersión para el cálculo del poder dióptrico de la lente intraocular. Rev. Cub. Oftalmol . 2014[acceso 24/03/2021];27(3):350-8. Disponible: Disponible: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/310 22.
Tsunehiro S, Shimizu K, Shoji N, Hiro-Oka H, Furukawa H. Prediction of intraocular lens position based on crystalline lens shape measured using anterior segment optical coherence tomography. Kitasato Med J. 2017[acceso 24/03/2021];47:110-7. Disponible en: Disponible en: https://www.kitasato-u.ac.jp/ktms/kaishi/pdf/KMJ47-2/KMJ47-2p110-117.pdf 25.
Martinez-Enriquez E, Pérez-Merino P, Durán-Poveda S, Jiménez-Alfaro I, Marcos S. Estimation of intraocular lens position from full crystalline lens geometry: towards a new generation of intraocular lens power calculation formulas. Scientific REPorTS. 2018;8:9829. DOI: https://doi.org/10.1038/s41598-018-28272-628.
Díaz Granados JF, Araque R, Rodríguez M F, Cifuentes D. Resultados refractivos y selección del poder del lente intraocular en cirugía de catarata por facoemulsificación. Rev. Sociedad Colombiana de Oftalmología. 2016[acceso 24/03/2021];49(1):16-23. Disponible en: Disponible en: https://docs.bvsalud.org/biblioref/2018/08/908947/resultados-refractivos.pdf 29.
Hernández López I. Comparación de Las fórmulas SRK/T, Hoffer Q, Barret Universal y HBRF para el cálculo del lente intraocular en la cirugía de catarata. Rev. Cub. Oftalmol . 2021[acceso 24/06/2021]. Disponible en: Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S086421762021000400002&lng=es 32.