Evaluación del desarrollo de habilidades y destrezas quirúrgicas en cirugía de catarata por residentes e instructores, empleando el Simulador de Cirugía EyeSi®

Serrano-Martínez P, Nava-García JA, Rodríguez-García A, Páez-Garza JH
Full text How to cite this article

Language: Spanish
References: 8
Page: 19-24
PDF size: 180.15 Kb.


Key words:

Surgical Simulator EyeSi®, cataract.

ABSTRACT

Introduction: The eye surgery simulator EyeSi® offers a virtual experience in ophthalmologic surgical cases very similar to real surgery. In this paper results between residents and instructors of cataract surgery were compared. Categories evaluated were: instrument handling, forceps, capsulorhexis and «divide and conquer» technique. Method: 14 residents from the Tecnológico de Monterrey Ophthalmology Program and 7 instructors from the cataract surgery program were evaluated using the EyeSi® surgical exercises. Results from such categories were compared. Results: Attendants obtained higher grades than the residents, mainly in instrument handling and capsulorhexis. Discussion and conclusion: It was demonstrated that the EyeSi® surgical simulator is a useful parameter for evaluation of surgical skills. It is also a useful tool in institutional education, because it allows residents to acquire surgical skills and attendants to develop new surgical techniques without complications in real patients.


REFERENCES

  1. EyeSi Ophthalmosurgical Simulator User Guide. Mannheim,Germany:VRMagic; 2008.

  2. EyeSi Ophthalmosurgical Simulator Software Release 2.4. Mannheim, Germany:VRMagic; 2008.

  3. EyeSi Ophthalmosurgical Simulator For Educators. Mannheim, Germany:VRMagic; 2008.

  4. Mahr MA, Hodge DO. Construct validity of anterior segment anti-tremor and forceps surgical simulator training modules. Attending versus resident surgeon performance. J Cataract Refract Surg 2008; 34:980-985.

  5. Mahr, MA. Cover Story. The Eyesi Ophthalmic Surgical Simulator. Cataract and Refractive Surgery Today. May 2008.

  6. Doyle L, Gauthier N, Ramanathan S y cols. A simulator to explore the role of haptic feedback in cataract surgical training. Stud Health Technol Inform 2008;132:106-111.

  7. Leuschke R, Bhandari A, Sires B y cols. Low cost eye surgery simulator with skill assessment component. Stud Health Technol Inform. 2007; 125:286-291.

  8. Henderson BA, Ali R. Teaching and assessing competence in cataract surgery. Curr Opin Ophthalmol. 2007;18(1):27-31.