medigraphic.com
SPANISH

Acta Ortopédica Mexicana

ISSN 2992-8036 (Electronic)
ISSN 2306-4102 (Print)
Órgano Oficial del Colegio Mexicano de Ortopedia y Traumatología
  • Contents
  • View Archive
  • Information
    • General Information        
    • Directory
  • Publish
    • Instructions for authors        
  • medigraphic.com
    • Home
    • Journals index            
    • Register / Login
  • Mi perfil

2022, Number 6

<< Back Next >>

Acta Ortop Mex 2022; 36 (6)

Surgical wound dehiscence and exposed hardware. Infection foretold?

Moril-Peñalver L, Sevilla-Monllor A, Saura-Sánchez E, Verdú-Aznar C, Lizaur-Utrilla A, López-Prats F
Full text How to cite this article 10.35366/111873

DOI

DOI: 10.35366/111873
URL: https://dx.doi.org/10.35366/111873

Language: Spanish
References: 8
Page: 385-388
PDF size: 188.01 Kb.


Key words:

Monteggia fracture-dislocations, open fracture, surgical wound dehiscence, hardware exposure.

ABSTRACT

Introduction: surgical wound dehiscence with exposure of internal fixation material is a serious problem in orthopedic surgery and an important factor for infection. Objective: presentation of an unusual case of an adult patient with surgical wound dehiscence and complete exposure of 20 cm of the ulnar plate after six years of surgery, without infection signs, with bone healing and skin behind the plate. Case presentation: 39-year-old man with an open Gustilo II Monteggia fracture-dislocation multifracture. The patient had a history of drug dependence. He had an open reduction and internal fixation with an ulnar reconstruction plate. The patient did not have any follow-up. After six years of the surgery, there was a complete exposure of the plate (20 cm) without infection and healing of the fracture with misalignment. After removing the plate, we observed spontaneous epithelialization attached to the bone bed. Skin coverage was complete at two months. Conclusion: although unusual, bone consolidation without infection is possible in an open fracture with long-standing exposure to a forearm plate in the adult.


REFERENCES

  1. Melhem E, Bayoud W, Ghanem I. Bone healing is achievable despite extensive wound dehiscence and wide plate and screws exposure in children. Orthop Traumatol Surg Res. 2019; 105(4): 757-60.

  2. Rightmire E, Zurakowski D, Vrahas M. Acute infections after fracture repair: management with hardware in place. Clin Orthop Relat Res. 2008; 466(2): 466-72.

  3. Acklin YP, Bircher A, Morgenstern M, Richards RG, Sommer C. Benefits of hardware removal after plating. Injury. 2018; 49 Suppl 1: S91-5.

  4. Merritt K, Dowd JD. Role of internal fixation in infection of open fractures: studies with Staphylococcus aureus and Proteus mirabilis. J Orthop Res. 1987; 5(1): 23-8.

  5. Dellinger EP, Miller SD, Wertz MJ, Grypma M, Droppert B, Anderson PA. Risk of infection after open fracture of the arm or leg. Arch Surg. 1988; 123(11): 1320-7.

  6. Trampuz A, Zimmerli W. Diagnosis and treatment of infections associated with fracture-fixation devices. Injury. 2006; 37 Suppl 2: S59-66.

  7. Wang C, Zhang Y, Qu H. Negative pressure wound therapy for closed incisions in orthopedic trauma surgery: a meta-analysis. J Orthop Surg Res. 2019; 14(1): 427.

  8. Berkes M, Obremskey WT, Scannell B, Ellington JK, Hymes RA, Bosse M; Southeast Fracture Consortium. Maintenance of hardware after early postoperative infection following fracture internal fixation. J Bone Joint Surg Am. 2010; 92(4): 823-8.




Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6

2020     |     www.medigraphic.com

Mi perfil

C?MO CITAR (Vancouver)

Acta Ortop Mex. 2022 Nov-Dic;36